GoodsCode.cs 16 KB

123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303304305306307308309310311312313314315316317318319320321322323324325326327328329330331332333334335336337338339340341342343344345346347348349350351352353354355356357358359360361362363364365366367368369370371372373374375376377378379380381382383384385386387388389390391392393394395396397398399400401402403404
  1. 
  2. using System;
  3. using System.Collections.Generic;
  4. using System.ComponentModel;
  5. using System.Data;
  6. using Curtain.DataAccess;
  7. using Curtain.Extension.ExObjectConvert;
  8. using Curtain.Extension.ExSystemData;
  9. using Curtain.Framework.Json;
  10. using Curtain.Helpers;
  11. using Curtain.Log;
  12. using Curtain.Net.Sockets.PLC;
  13. using Curtain.Net.Sockets.PLC.Model;
  14. using Curtain.Net.Sockets.PLC.Model.Siemens;
  15. namespace PLC_S.ServerModel
  16. {
  17. /// <summary>
  18. /// 返回产品型号等信息
  19. /// </summary>
  20. public class GoodsCode : SocketServer<SimpleSocketServerModel>, IShowFormLog, IWindowsServer
  21. {
  22. public Dictionary<string, PLC_S_GC> PLC_FLAGS = new Dictionary<string, PLC_S_GC>();
  23. public const string M_NAME = "GC";
  24. private readonly Logger logger = Logger.CreateLogger(M_NAME);
  25. private readonly LogInfo logger_t = new LogInfo();
  26. private readonly LogInfo logger_e = new LogInfo();
  27. private bool _S_STOP = false;
  28. public int Interval
  29. {
  30. get;
  31. set;
  32. }
  33. public string EPTS_CODE
  34. {
  35. get;
  36. set;
  37. }
  38. public GoodsCode()
  39. {
  40. logger.FileExistDays = 30;
  41. logger.FilePrefix = "";
  42. logger.FileSuffix = M_NAME;
  43. logger.LevelOneFile = true;
  44. logger.FileNameWithoutDate = true;
  45. logger_t.SubFolderFormat = "<name>";
  46. logger_t.FileExistDays = 30;
  47. logger_t.LevelOneFile = true;
  48. logger_e.FileExistDays = 10;
  49. this.Model.FormatType = CommandFormatType.StartStopChar;
  50. this.ServerStarting += ServerSocket_ServerStarting;
  51. this.ServerStarted += ServerSocket_ServerStarted;
  52. this.ServerStoping += ServerSocket_ServerStoping;
  53. this.ServerStoped += ServerSocket_ServerStoped;
  54. this.ServerMessage += ServerSocket_ServerMessage;
  55. this.Received += ServerSocket_Received;
  56. }
  57. #region Server
  58. public IFormLogShow FormLogShow
  59. {
  60. get;
  61. set;
  62. }
  63. private void ServerSocket_ServerStarting(object sender, CancelEventArgs e)
  64. {
  65. try
  66. {
  67. _S_STOP = false;
  68. logger.OutputTrace($"{M_NAME}_ServerStarting");
  69. }
  70. catch { }
  71. }
  72. private void ServerSocket_ServerStarted(object sender, EventArgs e)
  73. {
  74. try
  75. {
  76. _S_STOP = false;
  77. logger.OutputTrace($"{M_NAME}_ServerStarted");
  78. }
  79. catch { }
  80. }
  81. private void ServerSocket_ServerStoping(object sender, CancelEventArgs e)
  82. {
  83. try
  84. {
  85. _S_STOP = false;
  86. logger.OutputTrace($"{M_NAME}_ServerStoping");
  87. }
  88. catch { }
  89. }
  90. private void ServerSocket_ServerStoped(object sender, EventArgs e)
  91. {
  92. try
  93. {
  94. _S_STOP = false;
  95. logger.OutputTrace($"{M_NAME}_ServerStoped");
  96. }
  97. catch { }
  98. }
  99. private void ServerSocket_ServerMessage(object sender, ServerMessageEventArgs e)
  100. {
  101. try
  102. {
  103. _S_STOP = false;
  104. string message = e.ToString();
  105. string cip = e?.Client?.IP;
  106. if (e.Type == ServerMessageType.Debug)
  107. {
  108. Logger.Debug(message, $"{M_NAME}-T[{cip}]", logger_t);
  109. }
  110. if (e.Type == ServerMessageType.Error)
  111. {
  112. Logger.Error(e.Exception, message, $"{M_NAME}-E[{cip}]", logger_e);
  113. }
  114. if (e.Type == ServerMessageType.Trace)
  115. {
  116. Logger.Trace(message, $"{M_NAME}-T[{cip}]", logger_t);
  117. }
  118. if (e.Type == ServerMessageType.Warning)
  119. {
  120. Logger.Warn(message, $"{M_NAME}-E[{cip}]", logger_e);
  121. }
  122. FormLogShow?.ShowLog("ServerMessage=" + message);
  123. }
  124. catch { }
  125. }
  126. #endregion
  127. /// <summary>
  128. /// 返回产品型号
  129. /// </summary>
  130. /// <param name="sender"></param>
  131. /// <param name="e"></param>
  132. private void ServerSocket_Received(object sender, ReceiveSession e)
  133. {
  134. PLC_S_GC plc_s = null;
  135. string cIP = e?.Client?.IP;
  136. string logKeyT = $"{M_NAME}-T[{cIP}]";
  137. string logKeyE = $"{M_NAME}-E[{cIP}]";
  138. _S_STOP = false;
  139. SocketClient<SiemensS7_1200Model> plc = null;
  140. Logger LoggerT = null;
  141. try
  142. {
  143. LoggerT = Logger.CreateLogger(logKeyT, logger_t);
  144. lock (LoggerT)
  145. {
  146. LoggerT.BeginTracking();
  147. string outputMessage = e.ToString();
  148. Logger.Trace(outputMessage, logKeyT, logger_t);
  149. FormLogShow?.ShowLog(outputMessage);
  150. if (string.IsNullOrWhiteSpace(e.Content))
  151. {
  152. outputMessage = "接收数据为空";
  153. Logger.Warn(outputMessage, logKeyT, logger_t);
  154. Logger.Warn(outputMessage, logKeyE, logger_e);
  155. FormLogShow?.ShowLog(outputMessage);
  156. return;
  157. }
  158. outputMessage = e.Content;
  159. Logger.Trace(outputMessage, logKeyT, logger_t);
  160. FormLogShow?.ShowLog(outputMessage);
  161. string[] c = e.Content.Split('#');
  162. string flag = null;
  163. if (c.Length > 0)
  164. {
  165. flag = c[0];
  166. }
  167. string barcode = null;
  168. if (c.Length > 1)
  169. {
  170. barcode = c[1];
  171. }
  172. if (string.IsNullOrWhiteSpace(flag))
  173. {
  174. outputMessage = $"[{e.Content}]接收设备代码为空";
  175. Logger.Warn(outputMessage, logKeyT, logger_t);
  176. Logger.Warn(outputMessage, logKeyE, logger_e);
  177. FormLogShow?.ShowLog(outputMessage);
  178. return;
  179. }
  180. plc_s = GetPLC_S_GC(flag, e, logKeyE);
  181. if (plc_s == null)
  182. {
  183. outputMessage = $"[{e.Content}]设备代码[{flag}]未找到ini配置或有错误";
  184. Logger.Error(null, outputMessage, logKeyT, logger_t);
  185. Logger.Error(null, outputMessage, logKeyE, logger_e);
  186. FormLogShow?.ShowLog(outputMessage);
  187. return;
  188. }
  189. outputMessage = $"[{e.Content}]PLC_Connect={JsonHelper.FromObject(plc_s)}";
  190. Logger.Trace(outputMessage, logKeyT, logger_t);
  191. FormLogShow?.ShowLog(outputMessage);
  192. plc = new SocketClient<SiemensS7_1200Model>();
  193. plc.Connect(plc_s.IP, plc_s.Port);
  194. //outputMessage = $"[{e.Content}]PLC_Connect=[{plc_s.IP}:{plc_s.Port}]";
  195. //Logger.Trace(outputMessage, logKeyT, logger_t);
  196. //FormLogShow?.ShowLog(outputMessage);
  197. if (string.IsNullOrWhiteSpace(barcode) ||
  198. barcode == "0" ||
  199. barcode.Length != 11 ||
  200. barcode.StartsWith("0"))
  201. {
  202. outputMessage = $"[{e.Content}]接收条码格式错误";
  203. Logger.Warn(outputMessage, logKeyT, logger_t);
  204. Logger.Warn(outputMessage, logKeyE, logger_e);
  205. FormLogShow?.ShowLog(outputMessage);
  206. SendError(plc_s, e, logKeyT, logKeyE, plc);
  207. return;
  208. }
  209. DataRow codeRow = GetGoodsCode(barcode, e, logKeyE);
  210. if (codeRow == null)
  211. {
  212. outputMessage = $"[{e.Content}]此条码[{barcode}]不存在";
  213. Logger.Warn(outputMessage, logKeyT, logger_t);
  214. Logger.Warn(outputMessage, logKeyE, logger_e);
  215. FormLogShow?.ShowLog(outputMessage);
  216. SendError(plc_s, e, logKeyT, logKeyE, plc);
  217. return;
  218. }
  219. string code = codeRow["goodscode"].ToString();
  220. string intcode = codeRow["seatcovercode"].ToString();
  221. outputMessage = $"[{e.Content}]产品型号={code}[{intcode}]";
  222. Logger.Trace(outputMessage, logKeyT, logger_t);
  223. FormLogShow?.ShowLog(outputMessage);
  224. if (string.IsNullOrWhiteSpace(intcode))
  225. {
  226. outputMessage = $"[{e.Content}]此条码[{barcode}]未设置型号代码";
  227. Logger.Error(null, outputMessage, logKeyT, logger_t);
  228. Logger.Error(null, outputMessage, logKeyE, logger_e);
  229. FormLogShow?.ShowLog(outputMessage);
  230. SendError(plc_s, e, logKeyT, logKeyE, plc);
  231. return;
  232. }
  233. outputMessage = $"[{e.Content}]SET_GoodsCode=[{intcode}]{plc_s.Add_Code + plc_s.Add_CodeNum}";
  234. Logger.Trace(outputMessage, logKeyT, logger_t);
  235. FormLogShow?.ShowLog(outputMessage);
  236. PLCResult p_r = plc.Write<short>(plc_s.Add_Code, plc_s.Add_CodeNum, (short)(intcode.ToInt32()));
  237. outputMessage = $"[{e.Content}]END_GoodsCode=[{p_r}]{plc_s.Add_Code + plc_s.Add_CodeNum}";
  238. Logger.Trace(outputMessage, logKeyT, logger_t);
  239. FormLogShow?.ShowLog(outputMessage);
  240. //2.状态(int)【0:无,1:PLC等待读取;2.PLC读取完成】
  241. outputMessage = $"[{e.Content}]SET_F_Code=[1]{plc_s.Add_F_Code + plc_s.Add_F_CodeNum}";
  242. Logger.Trace(outputMessage, logKeyT, logger_t);
  243. FormLogShow?.ShowLog(outputMessage);
  244. p_r = plc?.Write<short>(plc_s.Add_F_Code, plc_s.Add_F_CodeNum, (short)1);
  245. outputMessage = $"[{e.Content}]END_F_Code=[{p_r}]{plc_s.Add_F_Code + plc_s.Add_F_CodeNum}";
  246. Logger.Trace(outputMessage, logKeyT, logger_t);
  247. FormLogShow?.ShowLog(outputMessage);
  248. //3.通信异常标识(int)【0:正常,1:后台处理异常,报警】
  249. outputMessage = $"[{e.Content}]SET_ErrorNum=[0]{plc_s.Add_Error + plc_s.Add_ErrorNum}";
  250. Logger.Trace(outputMessage, logKeyT, logger_t);
  251. FormLogShow?.ShowLog(outputMessage);
  252. p_r = plc?.Write<short>(plc_s.Add_Error, plc_s.Add_ErrorNum, (short)0);
  253. outputMessage = $"[{e.Content}]END_ErrorNum=[{p_r}]{plc_s.Add_Error + plc_s.Add_ErrorNum}";
  254. Logger.Trace(outputMessage, logKeyT, logger_t);
  255. FormLogShow?.ShowLog(outputMessage);
  256. }
  257. }
  258. catch (Exception ex)
  259. {
  260. FormLogShow?.ShowLog($"[{e.Content}]ERROR={ex.Message}");
  261. if (plc_s != null)
  262. {
  263. Logger.Error(ex, $"[{e.Content}]ERROR", logKeyT, logger_t);
  264. Logger.Error(ex, $"[{e.Content}]ERROR", logKeyE, logger_e);
  265. SendError(plc_s, e, logKeyT, logKeyE, plc);
  266. }
  267. else
  268. {
  269. Logger.Error(ex, $"[{e.Content}]ERROR-NOFLAG", logKeyT, logger_t);
  270. Logger.Error(ex, $"[{e.Content}]ERROR-NOFLAG", logKeyE, logger_e);
  271. }
  272. }
  273. finally
  274. {
  275. LoggerT?.EndTracking();
  276. plc?.Disconnect();
  277. plc?.Close();
  278. //e.ReturnMessage("0000");
  279. }
  280. }
  281. private void SendError(PLC_S_GC plc_s, ReceiveSession e, string loggerNameT,
  282. string loggerNameE, SocketClient<SiemensS7_1200Model> plc)
  283. {
  284. try
  285. {
  286. //using (SocketClient<SiemensS7_1200Model> plc = new SocketClient<SiemensS7_1200Model>())
  287. {
  288. string outputMessage = $"[{e.Content}]SET_ErrorNum=[1]{plc_s.Add_Error + plc_s.Add_ErrorNum}";
  289. Logger.Trace(outputMessage, loggerNameT, logger_t);
  290. FormLogShow?.ShowLog(outputMessage);
  291. PLCResult p_r = plc?.Write<short>(plc_s.Add_Error, plc_s.Add_ErrorNum, (short)1);
  292. outputMessage = $"[{e.Content}]END_ErrorNum=[{p_r}]{plc_s.Add_Error + plc_s.Add_ErrorNum}";
  293. Logger.Trace(outputMessage, loggerNameT, logger_t);
  294. FormLogShow?.ShowLog(outputMessage);
  295. }
  296. }
  297. catch (Exception ex)
  298. {
  299. Logger.Error(ex, $"[{e.Content}]ERROR-SendError", loggerNameT, logger_t);
  300. Logger.Error(ex, $"[{e.Content}]ERROR-SendError", loggerNameE, logger_e);
  301. FormLogShow?.ShowLog($"[{e.Content}]ERROR-SendError={ex.Message}");
  302. }
  303. }
  304. private DataRow GetGoodsCode(string barcode, ReceiveSession e, string loggerName)
  305. {
  306. IDataAccess dataAccess = null;
  307. try
  308. {
  309. dataAccess = PLC_S_DataAccess.GetDataAccess(e);
  310. string sqlString = "select g.goodscode, g.seatcovercode\n" +
  311. " from tp_pm_groutingdailydetail gdd\n" +
  312. " inner join tp_mst_goods g\n" +
  313. " on g.goodsid = gdd.goodsid\n" +
  314. " where gdd.barcode = :barcode";
  315. DataTable dataTable = dataAccess.ExecuteDatatable(sqlString, new CDAParameter(":barcode", barcode));
  316. if (dataTable.HasData())
  317. {
  318. return dataTable.Rows[0];
  319. }
  320. return null;
  321. }
  322. catch (Exception ex)
  323. {
  324. Logger.Error(ex, $"[{e.Content}]ERROR-GetGoodsCode", loggerName, logger_e);
  325. FormLogShow?.ShowLog($"[{e.Content}]ERROR-GetGoodsCode={ex.Message}");
  326. return null;
  327. }
  328. finally
  329. {
  330. dataAccess?.Close();
  331. }
  332. }
  333. private PLC_S_GC GetPLC_S_GC(string flag, ReceiveSession e, string loggerName)
  334. {
  335. try
  336. {
  337. flag = M_NAME + flag;
  338. if (PLC_FLAGS.ContainsKey(flag))
  339. {
  340. return PLC_FLAGS[flag];
  341. }
  342. else
  343. {
  344. PLC_S_GC plc_s = new PLC_S_GC();
  345. INIHelper ini = INIHelper.Create($@"PLC_S_INI\PLC_S_{M_NAME}.ini");
  346. plc_s.IP = ini.Read(flag, "IP");
  347. plc_s.Port = ini.Read(flag, "Port").ToInt32();
  348. plc_s.Add_Code = ini.Read(flag, "Add_Code");
  349. plc_s.Add_CodeNum = ini.Read(flag, "Add_CodeNum");
  350. plc_s.Add_F_Code = ini.Read(flag, "Add_F_Code");
  351. plc_s.Add_F_CodeNum = ini.Read(flag, "Add_F_CodeNum");
  352. plc_s.Add_Error = ini.Read(flag, "Add_Error");
  353. plc_s.Add_ErrorNum = ini.Read(flag, "Add_ErrorNum");
  354. PLC_FLAGS.Add(flag, plc_s);
  355. return plc_s;
  356. }
  357. }
  358. catch (Exception ex)
  359. {
  360. Logger.Error(ex, $"[{e.Content}]ERROR-GetPLC_S_GC", loggerName, logger_e);
  361. FormLogShow?.ShowLog($"[{e.Content}]ERROR-GetPLC_S_GC={ex.Message}");
  362. return null;
  363. }
  364. }
  365. }
  366. }